The sensor outputs voltage levels that correspond to the measured ambient pressure. According to the sensor's spec sheet, the sensor outputs 0.5 volts DC at 0 pounds per square inch, and has a pressure span of 100 pounds per square inch for an output voltage differential of 4.0 volts DC. With that information, one can derive a simple linear equation as follows: